Maintenance Parts Pro is pleased to offer procurement options for United Electric Controls Company part number V22F-183, a Switch Flow product we carry that is listed with the NSN 5930-01-339-7831 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number V22F-183 specifically traces back to United Electric Controls Company through CAGE Code 14314, as well as belongs to the FSC [FSC] as per its NSN of 5930-01-339-7831. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number V22F-183 using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-339-7831 Item PartTypeName: SWITCH,FLOW | 5930 | 013397831 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1A20315H01 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND HUMIDITY RESISTANT AND SALT SPRAY RESISTANT |
AWTN | OPERATING TEMP RATING | -29.0 DEG CELSIUS MINIMUM AND 52.0 DEG CELSIUS MAXIMUM |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
AXGY | MOUNTING METHOD | INLET CONNECTION AND OUTLET CONNECTION |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CSCF | TERMINAL TYPE | WIRE HOOK |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 3.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CTYX | CONTACT STIMULUS RATING | 0.80 ACTUATION POINT MINIMUM GALLONS PER MINUTE AND 0.90 ACTUATION POINT MAXIMUM GALLONS PER MINUTE AND 0.65 DEACTUATION POINT NOMINAL GALLONS PER MINUTE |
ABHP | OVERALL LENGTH | 4.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.740 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.250 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | RADAR SET AN/SPS 40D |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote