Maintenance Parts Pro is pleased to offer procurement options for Teledyne Wireless Inc part number BPF-W-999-999-11209, a Waveguide Assembly Filter product we carry that is listed with the NSN 5985-01-408-0583 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number BPF-W-999-999-11209 specifically traces back to Teledyne Wireless Inc through CAGE Code 56216, as well as belongs to the FSC [FSC] as per its NSN of 5985-01-408-0583. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number BPF-W-999-999-11209 using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-408-0583 Item PartTypeName: WAVEGUIDE ASSEMBLY,FILTER | 5985 | 014080583 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | S | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
BPF-W-999-999-11209 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AHSZ | Flange Outside Width | 1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE |
ZZZK | Specification/Standard Data | 94987-233817 MANUFACTURERS SOURCE CONTROL |
AHTA | Flange Outside Height | 1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE |
AHTN | Flange Connecting Hole Diameter | 0.169 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHTN | Flange Connecting Hole Diameter | 0.138 INCHES NOMINAL FIRST FLANGE ALL CONNECTION FACILITIES |
MATT | Material | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | Surface Treatment | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
FLEX | Flexibility | RIGID SINGLE TUBING SEGMENT |
AAJF | Thread Direction | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTFD | Waveguide Length | 3.995 INCHES MINIMUM AND 4.005 INCHES MAXIMUM |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
PRMT | Precious Material | SILVER |
AAJD | Thread Class | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
PMLC | Precious Material And Location | FLANGE SURFACE SILVER |
CQHN | Waveguide Outside Width | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
STYL | Style Designator | STRAIGHT TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CRFH | Waveguide Inside Width | 0.6165 INCHES MINIMUM AND 0.6245 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | Flange Style | CHOKE TYPE FIRST FLANGE |
CTCJ | Flange Style | COVER TYPE SECOND FLANGE |
CRLB | Waveguide Inside Height | 0.3085 INCHES MINIMUM AND 0.3135 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | Flange Quantity | 2 |
CSFC | Waveguide Outside Height | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
AHSY | Flange Inside Height | 0.309 INCHES MINIMUM FIRST FLANGE AND 0.313 INCHES MAXIMUM FIRST FLANGE |
AHSZ | Flange Outside Width | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
AHTA | Flange Outside Height | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
AHTD | Flange Depth | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHSY | Flange Inside Height | 0.394 INCHES MINIMUM SECOND FLANGE AND 0.396 INCHES MAXIMUM SECOND FLANGE |
AHSX | Flange Inside Width | 0.620 INCHES MINIMUM FIRST FLANGE AND 0.624 INCHES MAXIMUM FIRST FLANGE |
AHSX | Flange Inside Width | 0.705 INCHES MINIMUM SECOND FLANGE AND 0.707 INCHES MAXIMUM SECOND FLANGE |
AHTD | Flange Depth | 0.360 INCHES MINIMUM FIRST FLANGE AND 0.390 INCHES MAXIMUM FIRST FLANGE |
AHTW | Voltage Standing Wave Ratio | 1.4 |
AHTX | Insertion Loss In Decibels | 0.3 |