Maintenance Parts Pro is pleased to offer procurement options for Sensata Technologies Inc part number AP16-2R-7331-1, a Circuit Breaker product we carry that is listed with the NSN 5925-01-158-4168 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number AP16-2R-7331-1 specifically traces back to Sensata Technologies Inc through CAGE Code 81541, as well as belongs to the FSC [FSC] as per its NSN of 5925-01-158-4168. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number AP16-2R-7331-1 using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-158-4168 Item Description: CIRCUIT BREAKER | 5925 | 011584168 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP16-2R-7331-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | POLE QUANTITY | 2 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 0.6 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 4.000 MINIMUM SECOND LOCATION AND 40.000 MAXIMUM SECOND LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 6.000 MINIMUM FIRST LOCATION AND 50.000 MAXIMUM FIRST LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 125 PCT SECOND LOCATION AND 40.000 MAXIMUM AT 125 PCT SECOND LOCATION AND 0.850 MINIMUM AT 200 PCT SECOND LOCATION AND 4.000 MAXIMUM AT 200 PCT SECOND LOCATION AND 0.001 MINIMUM AT 400 PCT SECOND LOCATION AND 0.500 MAXIMUM |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 125 PCT FIRST LOCATION AND 50.000 MAXIMUM AT 125 PCT FIRST LOCATION AND 0.900 MINIMUM AT 200 PCT FIRST LOCATION AND 4.000 MAXIMUM AT 200 PCT FIRST LOCATION AND 0.010 MINIMUM AT 400 PCT FIRST LOCATION AND 0.090 MAXIMUM AT 40 |
FREQ | FREQUENCY IN HERTZ | 400.0 FIRST LOCATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote