Maintenance Parts Pro is pleased to offer procurement options for Lockheed Corp part number 9113C3004, a Capacitor Fixed Mica Dielectric product we carry that is listed with the NSN 5910-00-879-6050 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number 9113C3004 specifically traces back to Lockheed Corp through CAGE Code 87557, as well as belongs to the FSC [FSC] as per its NSN of 5910-00-879-6050. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number 9113C3004 using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-879-6050 Item PartTypeName: CAPACITOR,FIXED,MICA DIELECTRIC | 5910 | 008796050 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
VDM30F682G03 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBQ | CAPACITANCE VALUE PER SECTION | 6800.000 PICOFARADS SINGLE SECTION |
CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | 0.0 TO 70.0 SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.780 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.870 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.300 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.407 INCHES MINIMUM AND 0.469 INCHES MAXIMUM |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 1000.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -2.00 TO 2.00 PERCENT SINGLE SECTION |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0014 |
TEST | TEST DATA DOCUMENT | 87557-9113C3004 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |