Maintenance Parts Pro is pleased to offer procurement options for Idec Systems And Controls Corp part number RR2KP-U-120VAC, a Relay Electromagnetic product we carry that is listed with the NSN 5945-01-326-5790 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number RR2KP-U-120VAC specifically traces back to Idec Systems And Controls Corp through CAGE Code 60886, as well as belongs to the FSC [FSC] as per its NSN of 5945-01-326-5790. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number RR2KP-U-120VAC using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-326-5790 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013265790 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
RR2KP-U-120VAC | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.418 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.418 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AKDX | WINDING QUANTITY | 2 |
APCN | COIL QUANTITY | 2 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AGAV | END ITEM IDENTIFICATION | SEWAGE TREATMENT PLANT,ELTECH ENVIRO SYSTEMS CORP |
AJSS | FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNA | WINDING DC RESISTANCE RATING | 2.0 KILOHMS MINIMUM ALL WINDINGS AND 2.4 KILOHMS MAXIMUM ALL WINDINGS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CBME | CUBIC MEASURE | 6.376 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 11 PIN ALL FUNCTIONS |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 7.0 AMPERES AC AND 7.0 AMPERES DC INDUCTIVE LOAD |
CWJB | ENERGIZING ELEMENT POWER RATING | 2.2 VOLTS-AMPERES |
ABKW | OVERALL HEIGHT | 3.171 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
APNP | DUTY TYPE | CONTINUOUS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |