Maintenance Parts Pro is pleased to offer procurement options for Hamilton Sundstrand Corporation part number 26130011, a Valve Gate product we carry that is listed with the NSN 4810-00-987-3949 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number 26130011 specifically traces back to Hamilton Sundstrand Corporation through CAGE Code 99167, as well as belongs to the FSC [FSC] as per its NSN of 4810-00-987-3949. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number 26130011 using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
4810-00-987-3949 Item PartTypeName: VALVE,GATE | 4810 | 009873949 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
26130011 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
FEAT | SPECIAL FEATURES | PROOF PRESSURE 240 LBF/IN.2GA AT 800 DEG FEH; AMBIENT TEMP RANGE -65 TO +250 DEG FEH; OPENING PRESSURE (MIN) 20 LBF/IN.2GA; CLOSING PRESSURE (MIN) 5 LBF/IN.2GA; DUCT AIR TEMP RANGE -65 TO +800 DEG FEH; FLOW RATE 90 LBF/IN.2 |
CRWH | MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED | 250.0 DEG FAHRENHEIT AIR |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 18.0 DC AND 30.0 DC |
CYBZ | INLET RELATIONSHIP WITH OUTLET | NOT IDENTICAL |
ADST | BONNET ATTACHMENT METHOD | BOLTED |
AMPS | CURRENT RATING IN AMPS | 1.3 |
AAMW | FLANGE DIAMETER | 1.250 INCHES |
AQLR | VALVE OPERATION METHOD | SOLENOID |
AWLS | CONNECTION TYPE | FLANGE, ROUND W/O HOLES |
CCFG | VALVE SIZE | 1.250 INCHES |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | AIR SHUT-OFF VALVE, SOLENOID CONTROLLED |
CQCJ | MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED | 220.0 POUNDS PER SQUARE INCH AIR |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote