Maintenance Parts Pro is pleased to offer procurement options for Fluke Corporation part number 5790A-AF03OPT, a Voltage Standard product we carry that is listed with the NSN 6625-01-386-8852 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number 5790A-AF03OPT specifically traces back to Fluke Corporation through CAGE Code 89536, as well as belongs to the FSC [FSC] as per its NSN of 6625-01-386-8852. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number 5790A-AF03OPT using our provided form.
MRC | Criteria | Characteristic |
---|---|---|
SR-5 | THE MANUFACTURERS DATA | |
BHXZ | OUTPUT ACCURACY RATING IN PERCENT | -0.010 TO 0.010 |
BHYB | WARM-UP TIME FOR MAXIMUM ACCURACY IN MINUTES | 30.0 |
BHXX | ELECTROMOTIVE FORCE PRODUCTION METHOD | ELECTRONIC |
AARB | TERMINAL TYPE | CONNECTOR AND BINDING POST |
ABFY | OVERALL DEPTH | 24.800 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.000 INCHES NOMINAL |
SUPP | III SUPPLEMENTARY FEATURES | 5790A/AF-OPT03 IS CHECKED AND VERIFIED BY THE AEROSPACE GUIDENCE AND METROLOGY CENTER BEFORE BEING SHIPPED TOTHE PMEL LABS |
FAAZ | PHASE | SINGLE |
AARA | TERMINAL QUANTITY | 1 AND 5 |
SR-5 | MANUFACTURERS CODE | 4U744 |
CRTL | CRITICALITY CODE JUSTIFICATION | SUPP |
APQB | UNIT TYPE | ENCASED |
BHYC | PROTECTIVE DEVICE TYPE | FUSE |
FEAT | SPECIAL FEATURES | FREQUENCY RANGE 10HZ TO 1MHZ: VOLTAGE RANGE 700UV TO 1000V: TRACEABLE TO NATIONAL STANDARDS: 24PPM TOTAL UNCERTAINTY: AUTOMATIC AC MEASUREMENT: COMPATIBLE WITH FLUKE A40 AND A40A CURRENT SHUNTS: POWER UP SELF TEST: 4 SETS OF INPUT TERMINALS, 1 N TYPE AND 1 SET OF BINDING POST DEDICATED FOR AC MEASUREMENTS AND TRANSFER MODES. 2ND SET OFBINDING POSTS ARE FOR CURRENT SHUNTS: DIGITALDISPLAY SHOWN IN PPM,PCT,VOLTS AND RATIOS. 1200V INPUT PROTECTION ON ALL RANGES. GPIB/IEEE488,RS232C INTERFACES ARE INCLUDED |
AQYB | OUTPUT VOLTAGE RATING | 0.0 VOLTS MINIMUM AND 7.0 VOLTS MAXIMUM |
SR-5 | DESIGN CONTROL REFERENCE | 5790A/AF03OPT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
APCB | PORTABILITY | NONPORTABLE |
ABMK | OVERALL WIDTH | 17.000 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 110.0 VOLTS NOMINAL AND 220.0 VOLTS NOMINAL |