Maintenance Parts Pro is pleased to offer procurement options for Arnold Magnetics Corporation part number PHX800, a Power Supply product we carry that is listed with the NSN 6130-01-283-9011 for seamless identification. As this item is available for purchase today, be sure to fill out and submit the Request for Quote (RFQ) form on this page if you are interested in obtaining pricing information. All that we ask is that you share details like your budget, desired quantity, and expected fulfillment speed so that we can respond with the most fitting solutions for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside streamlined quotation processes, we aim to support our customers by providing as much relevant listing information and data with product offerings as possible. For example, part number PHX800 specifically traces back to Arnold Magnetics Corporation through CAGE Code 04879, as well as belongs to the FSC [FSC] as per its NSN of 6130-01-283-9011. Referencing such details, you can locate and procure exact specifications with ease. With our various practices in mind, do not hesitate to request a quote on part number PHX800 using our provided form.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-283-9011 Item PartTypeName: POWER SUPPLY | 6130 | 012839011 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
654342-2 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.620 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | FTF 15 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 126.5 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 207.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 253.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 11.4 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 12.6 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 128.2 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 141.7 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 4.7 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 5.2 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 52.2 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 57.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -25.0/71.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 150.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 3 SINGLE OPERATING POWER RQMT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.